Agarose pad protocol for yeast

[vc_column width=”1/1″][vc_row_inner][vc_column_inner width=”2/3″][vc_column_text]

Agarose pad mounting protocol for yeast

For full efficiency of the CherryTemp temperature controller, samples must be placed close to the CherryTemp thermalisation chip (<500µm). Therefore, preparing a thin agar pad is a critical step. The following protocol shows how to prepare thin agar pads and how to couple them to the CherryTemp technology.

[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″ el_class=”catmethods”][vc_column_text el_class=”centered_button”]

Picto-Categories-Yeast

[/vc_column_text][vc_column_text el_class=”centered_button”]

World fastest heater and cooler system for microscopy

Get information about how to thermalize your cells

[/vc_column_text][vc_button label=”YES ! GIVE ME MORE INFORMATIONS” target=”_self” size=”medium” style=”light” el_class=”centered_button” url=”https://www.cherrybiotech.com/?p=14180″][/vc_column_inner][/vc_row_inner][vc_separator height_2=”0″ height=”30″ show_border=”no_border”][vc_row_inner][vc_column_inner width=”2/3″][vc_column_text]

Step 1 : Align 3 microscope slides and stick lab tape on the 2 external ones (lengthwise).

[/vc_column_text][vc_column_text el_class=”centered_button”]

Agarose pad protocol for yeast_Fig-01

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 2: Drop melted agarose (50 to 100µl) on the middle one. Diameter of the pad must be around 1cm diameter.

[/vc_column_text][vc_column_text el_class=”centered_button”]

Agarose pad protocol for yeast_Fig-02

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 3: Top the agarose with another clean slide, placed perpendicularly. Apply gentle pressure and allow agarose to solidify.

[/vc_column_text][vc_column_text el_class=”centered_button”]

Agarose pad protocol for yeast_Fig-03

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 4: After agarose has solidified, gently remove the top slide by rotating. Agarose is ready to use, and the pad will be less than 500µM thick.

[/vc_column_text][vc_column_text el_class=”centered_button”]

Agarose pad protocol for yeast_Fig-04

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 5: Top the chip with our dedicated spacer (engraved arrows facing down, glass surface and microfluidic chamber facing up).

[/vc_column_text][vc_column_text]

Agarose pad protocol for yeast_Fig-05

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 6: Transfer the pad onto the CherryTemp chip. The pad must be centred on the thermalising pattern.

[/vc_column_text][vc_column_text]

Agarose pad protocol for yeast_Fig-06

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]Step 7: Pipet the yeast sample on the agar pad. Few microliters of medium are enough. For optimal cell density, first concentrate your sample by spinning cells.

Important: yeast cells must be centred on the agar pad.[/vc_column_text][vc_column_text]

Agarose pad protocol for yeast_Fig-07

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 8: Top with a high-resolution glass coverslip. The mounted sample is ready for observation in an upright microscope configuration.

[/vc_column_text][vc_column_text]

Agarose pad protocol for yeast_Fig-08

[/vc_column_text][vc_separator height_2=”0″ height=”20″ show_border=”no_border”][vc_column_text]

Step 9: Flip the mounted sample 180° for an inverted microscope configuration.

[/vc_column_text][vc_column_text]

Agarose pad protocol for yeast_Fig-09

[/vc_column_text][vc_separator height_2=”0″ height=”50″ show_border=”no_border”][vc_text_separator title=”Reference” icon=”none” border=”yes_border” margin=”20″][vc_column_text]

Methods adapted from P. Tran lab (Institut Curie) and from our user’s feedback.

[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/3″][vc_column_text]

Related Videos

[/vc_column_text][vc_column_text]

[embedyt] https://www.youtube.com/watch?v=wKgvw11UCE8[/embedyt]

[/vc_column_text][vc_separator height_2=”0″ height=”30″ show_border=”no_border”][vc_column_text]

Checkout other protocols

[/vc_column_text][vc_button label=”GO BACK TO METHODS” target=”_self” size=”medium” style=”light” el_class=”centered_button” url=”https://www.cherrybiotech.com/?p=9334″][/vc_column_inner][/vc_row_inner][/vc_column][vc_column width=”1/1″][vc_separator height_2=”0″ height=”50″ show_border=”no_border”][vc_row_inner][vc_column_inner width=”1/2″][vc_column_text]

CherryTemp thermal stage

[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/2″][vc_separator height_2=”0″ height=”50″ show_border=”no_border”][vc_column_text]

Discover the CherryTemp Heater Cooler

Ultra-fast shifts and temperature accuracy at the sample level

[/vc_column_text][vc_separator height_2=”0″ height=”50″ show_border=”no_border”][vc_button label=”Learn more” target=”_self” size=”medium” style=”light” url=”https://www.cherrybiotech.com/?p=5661″ el_class=”centered_button”][/vc_column_inner][/vc_row_inner][/vc_column]

Scroll to Top