Temperature control for microscope imaging: objective heater collar

[et_pb_section background_image=”https://www.cherrybiotech.com/wp-content/uploads/2014/03/soft-lithography-wafer-degrade1.jpg” background_color=”#ffffff” inner_shadow=”off” parallax=”off”][et_pb_row][et_pb_column type=”1_2″][et_pb_text admin_label=”Temperature control for microscope imaging: objective heater collar ” background_layout=”light” text_orientation=”left”]

Temperature control for microscope imaging: objective heater collar

[/et_pb_text][/et_pb_column][et_pb_column type=”1_2″][et_pb_image admin_label=”Image microscope” src=”https://www.cherrybiotech.com/wp-content/uploads/2014/03/Microscope1-e1396630683458.png” url_new_window=”off” animation=”off” module_class=”tuto” /][/et_pb_column][/et_pb_row][/et_pb_section][et_pb_section fullwidth=”off”][et_pb_row][et_pb_column type=”1_2″][et_pb_text admin_label=”Introduction” background_layout=”light” text_orientation=”left” module_class=”tuto”]

Introduction

The challenge with live-cell imaging is to maintain the cells in a physiological-like environment. Cell temperature is one of the many parameters to control during images acquisition. There are several temperature controllers available for users to choose from, and depending on the length and  type of experiments some systems will be best suited than others. Objective heater/cooler collars are used as a complement of already set-up temperature controller devices.

[/et_pb_text][et_pb_text admin_label=”How does it work?” background_layout=”light” text_orientation=”left” module_class=”tuto”]

Precision-30x28How does it work?

When the immersion objective, the oil (or water) and the microscope slide come in contact, the immersion objective acts like a heat sink, decreasing the actual sample temperature of several degrees (up to 10C) thus creating a thermal gradient on the sample.  Most of the temperature controllers do not pre-emptively correct the discrepancy between the pre-set sample temperature and the actual sample temperature when immersion objective is used. Thus, using an objective heater/cooler collar system is a requisite with most of the temperature controllers available on the market. Two types of temperature controlled objective collars can be found:

– Electronic heater collars surrounding the objective. They are used to control the heating of the objective.

– Fluidic collars composed of a metallic tubing with a circular shape fixed on the objective. In these, thermalized water flows into the collar and maintain, or change, the temperature of the immersion objective.

[/et_pb_text][et_pb_text admin_label=”Advantages” background_layout=”light” text_orientation=”left”]

Precision-30x28Advantages

High temperature range

The majority of objective heater collars ensure a temperature control from ambient to 43C. To reach below ambient temperature,  objective heater/cooler can be used, they are fluidic collars with liquid thermalization and a pumping system.

Enhance  sample temperature homogeneity

Temperature controlled objective collars can enhance temperature uniformity across the sample when using immersion objectives with any temperature controller. They prevent thermal gradient-induced artifacts.

[/et_pb_text][/et_pb_column][et_pb_column type=”1_2″][et_pb_text admin_label=”disadvantages” background_layout=”light” text_orientation=”left”]

Precision-30x28Disadvantages

Not self-sufficient

Temperature controlled objective collars have to be used in addition of other temperature control system (thermalized stages or perfusion systems).

Mono temperature control

Only one temperature at a time can be set for the objective heater collar. While other system  allow to pre-set two temperatures to rapidly shift from one to the other.

 Slow temperature shift

Objective heater collars have slow temperature shift (minutes). Objective heater collars are used in complement to  temperature controller devices. If temperature shift is required during the experiment, sample and objective temperature shift have to timely coincide to prevent the formation of  thermal gradient on the sample.

Requires experience user

It requires strong knowhow to understand artifacts generated by temperature controlled objective collars and to make the complete system work properly, especially to do temperature switch in ongoing experiments.

[/et_pb_text][et_pb_text admin_label=”Text” background_layout=”light” text_orientation=”left”]

[button link=”https://www.cherrybiotech.com/?p=534″ color=”red”] Use CherryTemp for temperature control[/button][button link=”https://www.cherrybiotech.com/?p=1404″ color=”red”] Discover yeast applications with CherryTemp[/button] [button link=”https://www.cherrybiotech.com/?p=1428″ color=”red”] Discover C.elegans applications with CherryTemp[/button][button link=”https://www.cherrybiotech.com/?p=1503″ color=”red”] Discover any cell type applications with CherryTemp[/button]

[/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section][et_pb_section fullwidth=”off” background_color=”#f04848″ inner_shadow=”off” parallax=”off”][et_pb_row][et_pb_column type=”1_2″][et_pb_cta admin_label=”Call To Action How does CherryTemp™ work?” title=”How does CherryTemp™ work?” button_url=”https://www.cherrybiotech.com/?p=534″ button_text=”Understand how it works” background_color=”#f04848″ use_background_color=”on” background_layout=”dark” text_orientation=”left”]

CherryTemp reaches such performance thanks to breaking edge microfluidics.

And thanks to a lot of work from our team to make sure Cherry Temp integrates seemlessly in your microscope set up.

[/et_pb_cta][/et_pb_column][et_pb_column type=”1_2″][et_pb_divider admin_label=”Divider” color=”#ffffff” show_divider=”off” height=”10″ /][et_pb_slider admin_label=”Slider” show_arrows=”on” show_pagination=”on” auto=”off” parallax=”off”][et_pb_slide background_image=”https://www.cherrybiotech.com/wp-content/uploads/2014/04/CherryTemp-microfluidic-platform-for-microscopy-temperature-control-3.jpg” background_color=”#ffffff” alignment=”center” background_layout=”dark” /][et_pb_slide background_image=”https://www.cherrybiotech.com/wp-content/uploads/2014/04/microfluidic-chip-for-live-cell-imaging.jpg” background_color=”#ffffff” alignment=”center” background_layout=”dark” /][et_pb_slide background_image=”https://www.cherrybiotech.com/wp-content/uploads/2014/04/confocal-inverted-microscope.png” background_color=”#ffffff” alignment=”center” background_layout=”dark” /][et_pb_slide background_image=”https://www.cherrybiotech.com/wp-content/uploads/2014/04/CherryTemp-and-CherryLoop-temperature-control-for-microscopy-2.jpg” background_color=”#ffffff” alignment=”center” background_layout=”dark” /][/et_pb_slider][/et_pb_column][/et_pb_row][/et_pb_section][et_pb_section fullwidth=”off”][et_pb_row][et_pb_column type=”1_4″][et_pb_blurb admin_label=”Blurb E njoy unprecendeted performance” title=”Enjoy the performance” url=”https://www.cherrybiotech.com/?p=312″ url_new_window=”off” image=”https://www.cherrybiotech.com/wp-content/uploads/2014/03/icon_rook2.png” alt=”Enjoy unprecendeted performance” animation=”off” background_layout=”light” text_orientation=”center”]

CherryTemp is the fastest temperature control in the 5-45°C range
[button color=”silver” link=”https://www.cherrybiotech.com/?p=312″] Learn more[/button]

[/et_pb_blurb][/et_pb_column][et_pb_column type=”1_4″][et_pb_blurb admin_label=”Blurb Work with any type of live cell” title=”Work with any of live cell” url_new_window=”off” image=”https://www.cherrybiotech.com/wp-content/uploads/2014/03/icon_grid-3×32.png” alt=”Work with any type of live cell” animation=”off” background_layout=”light” text_orientation=”center” url=”https://www.cherrybiotech.com/?p=1346″]

CherryTemp is adapted to all types of live cells including S. pombe and C. elegans
[button color=”silver” link=”https://www.cherrybiotech.com/?p=1346″]Learn more[/button]

[/et_pb_blurb][/et_pb_column][et_pb_column type=”1_4″][et_pb_blurb admin_label=”Blurb Start experiments in minutes” title=”Start experiments in minutes” url_new_window=”off” image=”https://www.cherrybiotech.com/wp-content/uploads/2014/03/icon_hourglass2.png” animation=”off” background_layout=”light” text_orientation=”center” url=”https://www.cherrybiotech.com/?p=896″]

CherryTemp is easy to use so that you focus on your research, not the instrument
[button color=”silver” link=”https://www.cherrybiotech.com/?p=896″] Learn more[/button]

[/et_pb_blurb][/et_pb_column][et_pb_column type=”1_4″][et_pb_divider admin_label=”Divider” color=”#ffffff” show_divider=”off” height=”15″ /][et_pb_text admin_label=”Text C elegans” background_layout=”light” text_orientation=”center” module_class=”elegans”]

S. pombe

See another example of temperature control with thermosensitive mutants

[button color=”silver” link=”https://www.cherrybiotech.com/?p=2131″] Application note[/button]

[/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section][et_pb_section fullwidth=”off”][et_pb_row][et_pb_column type=”4_4″][et_pb_cta admin_label=”Call To Action” title=”Want to know more about the system?” button_url=”https://www.cherrybiotech.com/contact-us” button_text=”Contact us” background_color=”#a40000″ use_background_color=”on” background_layout=”dark” text_orientation=”center”]

contact@cherrybiotech.com

[/et_pb_cta][/et_pb_column][/et_pb_row][/et_pb_section]

This is a unique website which will require a more modern browser to work! Please upgrade today!