Introduction to Diffraction Limit of Light
The optical microscopy, also called the light microscopy, is the oldest technique of microscopy which uses visible light and lenses to magnify images of very small samples. It is a standard technique frequently used within the fields of life and material science.
The first basic optical/light microscopes were developed during the 17th century. Nowadays, there are many variations available that enable high level resolutions and sample contrasts. Due to the computer-aided optical designing and automatic grinding methods, the quality of the images has improved exponentially with nearly no deviation [1].
However, optical microscopes still must overcome a critical limit in optical resolution caused by the diffraction of visible light wavefronts when they pass by a circular aperture at the rear focal plane of an objective, or lens.
The diffraction limit in the super-resolution microscopy context
There are many factors that can affect the final resolution of an optical imaging system like a microscope but the most relevant one is the diffraction limit of light.
The resolution of a microscope is inversely proportional to the wavelength of the light that is observed and directly proportional to the size of the objective itself.
Back in 1873, a German physicist called Ernst Abbe discovered how microscopes had limitations due to the diffraction of light. His research revealed that the resolution of a microscope is not related with the quality of the microscopy components themselves but due to the wavelength of the light used and the aperture of the optics.
Due to this phenomenon, a microscope is not able to resolve two objects if they are located to a distance that is shorter that λ/2NA, with λ being the wavelength of light and NA the numerical aperture of the imaging lens. Which means that the diffraction limit of light does not allow the microscope to differentiate between two objects divided by a lateral distance which is less than half of the wavelength of the light that has been used to image the sample [2-3].
Abbe discovered that images are made of an array of diffraction-limited spots with modifiable intensities which overlap one to each other to produce the final image. There are some options to overlap those constrains and maximize the spatial resolution and the image contrast to reduce the size of the spots that are limited by diffraction of light. For instance, it is possible to reduce the imaging wavelength, increase the numerical aperture or use an imaging medium that has a large refractive index [4].
Ultra fast temperature shift device for in vitro experiments under microscopy
How to overcome the Diffraction Limit of Light?
Super-Resolution Structured Illumination microscopy increases by two the spatial resolution over wide-field microscopy. In 2D/3D-SIM, lateral and axial resolutions are improved by 100nm and 250nm respectively.
Advantages of SR-SIM:
SR-SIM also allows to obtain 4D images at fast frame rate. Normally, it is necessary to have nine to filthen raw images for 2D/3D-SIM, while for STORM/PALM it is necessary to have at least one thousand.
The use of conventional fluorophores is possible giving access to existing biological mutated cell lines.
Up to four different wavelength[1] can be used with Structure Illumination microscopy making this technique very useful to co-localize or access to multiple highly-resolved information inside cells and organelles.
Finally, the sample preparation for SR-SIM observations is easier than other super-resolution techniques such as STED or STLM[2].
Limitations of SR-SIM
This super resolution microscopy technique is very sensitive to out-of-focus light and it is very hard to focus in samples that are thick or those which are densely labelled[3].
In addition, whereas PALM/STORM or STED techniques can reach a 20nm lateral diffraction limit, Structured-illumination microscopy is limited to 200nm[4].
Finally, some artefacts may be generated during the image reconstruction which can damage the quality of the image [5].
References
[1] Sydor AM, Czymmek KJ, Puchner EM, Mennella V. Super-Resolution Microscopy: From Single Molecules to Supramolecular Assemblies. Trends Cell Biol [Internet]. 2015 [cited 2017 Jun 15];25:730–48. http://www.cell.com/trends/cell-biology/pdf/S0962-8924(15)00191-9.pdf
[2] Wegel E, Göhler A, Lagerholm BC, Wainman A, Uphoff S, Kaufmann R, et al. Imaging cellular structures in super-resolution with SIM, STED and Localisation Microscopy: A practical comparison. Sci Rep [Internet]. 2016;6(1):27290. http://www.nature.com/articles/srep27290
[3] Jost A, Heintzmann R. Superresolution Multidimensional Imaging with Structured Illumination Microscopy. Annu Rev Mater Res [Internet]. 2013 Jul [cited 2017 Jun 16];43(1):261–82. http://www.annualreviews.org/doi/10.1146/annurev-matsci-071312-121648
[4] Henriques R, Mhlanga MM. PALM and STORM: What hides beyond the Rayleigh limit? Biotechnol J [Internet]. 2009 Jun [cited 2017 Jun 21];4(6):846–57. http://doi.wiley.com/10.1002/biot.200900024
[5] Kraus F, Miron E, Demmerle J, Chitiashvili T, Budco A, Alle Q, et al. Quantitative 3D structured illumination microscopy of nuclear structures. Nat Protoc [Internet]. 2017;12(5):1011–28. http://www.nature.com/doifinder/10.1038/nprot.2017.020
FAQ
The diffraction limit of light is a critical limit in optical resolution. It is caused by the diffraction of visible light wavefronts as they pass by a circular aperture. This aperture is located at the rear focal plane of an objective lens. This phenomenon is considered the most relevant factor affecting the final resolution of an optical imaging system. A microscope is not able to resolve two objects if they are located at a distance shorter than $\\lambda/2NA$. The variable $\\lambda$ represents the wavelength of light, while $NA$ is the numerical aperture of the imaging lens. This means that the diffraction limit does not permit the microscope to differentiate between two objects when they are divided by a lateral distance. This distance must be less than half of the wavelength of the light used for imaging.
The limitations of microscopes caused by the diffraction of light were discovered by a German physicist named Ernst Abbe in 1873\. His research revealed that the resolution of a microscope is not related to the quality of the microscopy components themselves. It was found to be due to the wavelength of the light being used and the aperture of the optics. The resolution is understood to be inversely proportional to the wavelength of the light that is observed. It is also directly proportional to the size of the objective itself. It was also discovered by Abbe that images are made of an array of diffraction-limited spots. These spots have modifiable intensities. They overlap one to another to produce the final image.
Super-Resolution Structured Illumination Microscopy (SR-SIM) increases the spatial resolution over wide-field microscopy by a factor of two. Both lateral and axial resolutions are improved, by 100nm and 250nm respectively. The technique also permits 4D images to be obtained. This can be done at a fast frame rate. This speed is possible because only nine to fifteen raw images are normally necessary for 2D or 3D-SIM reconstruction. Other techniques, such as STORM or PALM, require at least one thousand images. Another benefit is that the use of conventional fluorophores is possible. This gives researchers access to existing biological mutated cell lines. Up to four different wavelengths can also be used, making the technique useful for co-localization. Finally, the preparation of samples for SR-SIM observation is described as easier than for other super-resolution techniques.
Several limitations are associated with the SR-SIM technique. The method is described as very sensitive to out-of-focus light. This sensitivity makes it very hard to focus when samples are thick. It is also difficult to focus on samples that are densely labelled. A further limitation is related to the achievable resolution. While techniques like PALM, STORM, or STED can reach a 20nm lateral diffraction limit, SR-SIM is limited to 200nm. Finally, issues can arise during the image reconstruction step. It is noted that some artefacts may be generated during this process. These potential artefacts can damage the quality of the final image.